HOMEPRODUCTS RAILWAY CABLES

 

G7621 Trackside Communications Cables

 

Application:

The cables are designed for installation in trackside bracket runs and for use in open locations (type1) or in tunnels or underground locations (type2).

Standards:

LUL Spec G7621 A2 type 1 (for PVC sheath)

LUL Spec G7621 A2 type 2 (for LSZH sheath)

Construction:

Conductors

Solid plain copper, 0.63/0.9 mm nominal diameter.

Insulation

Cellular polyethylene.

Cabling Element

Two insulated conductors are twisted together to form a pair.

Core Wrapping

Non-hygroscopic plastic tape with overlapping.

Outer Sheath

PVC/LSZH sheath, coloured violet.

Core Identification

1 Pair Cable: Blue/White

3 Pair Cable: Blue/White Orange/White Green/White

Electrical Characteristics at 20℃:

Nominal Conductor Diameter mm 0.63 0.9
Maximum Conductor Resistance
Average Value Ω/km 57.5 28
Individual Value Ω/km 59 29
Minimum Insulation Resistance @500 V DC MΩ.km 1500 1500
Maximum Average Mutual Capacitance nF/km 59 59
Maximum Average Capacitance Unbalance
Pair to Pair pF/460m 100 100
Pair to Earth pF/460m 1200 1200

Mechanical and Thermal Properties:

Minimum Bending Radius: 7.5×OD

Temperature Range: -30℃ to +70℃ (during operation);

                                -10℃ +55℃ (during installation)

Dimensions And Weight:

Cable Code No. of pairs Nominal Thickness of Sheath
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
0.63mm Conductor, 1.15mm Insulated Wire
RS7621A2/T1-02YY-1P0.63 1 2.5 7.0 60
RS7621A2/T1-02YY-3P0.63 3 2.5 9.0 90
0.9mm Conductor, 1.5mm Insulated Wire
RS7621A2/T1-02YY-1P0.9 1 2.5 8.0 70
RS7621A2/T1-02YY-3P0.9 3 2.5 10.0 120